Sign in →

Test Code RUBM or LAB3493 Rubella IgM, Serum

Specimen Requirements

Container Type:

Optimal: Gold

Acceptable: Red 

 

Optimal Collection Volume: 

4.5mL; full tube

Minimum Volume:

1 mL

Collection Instructions:

Gently invert the sample 5-6 times after collection.

Specimen Transport:

Refrigerate

Processing Instructions: 

1. Allow the specimen to clot for 30 minutes.

2. Centrifuge specimen within 2 hours of collection.

3. After centrifugation, specimen tubes without a gel barrier should have the serum aliquoted to a false bottom container.

4. Keep serum refrigerated until testing can be performed.

Specimen Stability

Specimen Type Temperature Time
Serum Refrigerated 7 days
Room Temperature 8 hours

Specimen Rejection Criteria

Hemolysis Mild OK; Moderate OK; Gross Reject
Lipemia Mild OK; Moderate OK; Gross Reject
Icterus Mild OK; Moderate OK; Gross Reject
Other Quantity not sufficient

Useful For

The presence of IgM antibodies to Rubella virus is an indication of recent exposure to the virus, either by prior infection or by vaccination.

Methodology

Bio-Rad BioPlex 2200: Multiplex flow immunoassay

Reference Ranges

 Test ID   Reference Range and Reporting Units
RUBM < 0.9 AI: Negative
0.9-1.0 AI: Equivocal
> 1.1 AI: Positive

AI = Antibody Index.

Day(s) Performed

Monday through Friday

Expected TAT

Same day or 1-2 days

Performing Laboratory

Bronson Laboratory, Chemistry - Kalamazoo

Sample Retention Time

7 days

CPT Code

86762

LOINC Code

24116-6