Sign in →

Test Code HCT or LAB289 Hematocrit, Blood

Important Note

Hematocrit and hemoglobin are separately ordered tests. 

Specimen Requirements

Container Type:

Optimal: EDTA Lavender Top, whole blood

 

 

 

Acceptable: EDTA Microtainer

Optimal Collection Volume:

3 mL

Minimum Volume:

1 mL or 0.4 mL in EDTA microtainer

Collection Instructions:

Gently invert the sample tube 5-6 times after collection to mix the blood.

Specimen Transport Temperature:

Refrigerated

Processing Instructions:

1. Keep the specimen as whole blood for testing.

2. Store the specimens refrigerated prior to testing.

3. Allow refrigerated samples to come to room temperature and mix well before analysis.

Specimen Stability

Specimen Type

Temperature

Time

Whole blood

Refrigerated

48 hours

Room Temperature

24 hours

Specimen Rejection Criteria

Hemolysis

Mild OK; Moderate OK; Gross Reject

Other

Clotted specimens are rejected.

Useful For

Measuring the amount of hematocrit in blood.

Methodology

Sysmex XN - Cumulative pulse height detection

Reference Ranges

Males (>12 years)

Test ID

Reference Range and Reporting Units

HCT

41-51%

 

Females (>12 years)

Test ID

Reference Range and Reporting Units

HCT

36-47%

 

Pediatrics

Test ID

Age Group

Reference Range and Reporting Units

HCT

0-1 day

42-61%

2-6 days

42-61%

7-14 days

39-60%

15-30 days

31-58%

1-6 months

28-45%

6 mth to 2 years

33-42%

2-6 years

34-42%

6-12 years

35-45%

 

Critical Values

Age group: > 3 months

  • Low: ≤ 15%
  • High: ≥ 75%

Age group: < 3 months

  • Low: ≤20%
  • High: ≥70%

Day(s) Performed

24/7

Expected TAT

Same day

Performing Laboratory

Bronson Laboratory, Hematology - Kalamazoo, Battle Creek, Paw Paw, South Haven

Sample Retention Time

7 days

CPT Code

85014

LOINC Code

4544-3

Related Tests