Test Code URDS or LAB2286 Drug Screen 6, Urine
Profile Information
Test ID |
Reporting Name |
Available Separately? |
Always Performed? |
---|---|---|---|
UAMP |
Amphetamine Screen |
Y |
Y |
UBARB |
Barbiturate Screen |
Y |
Y |
UBENZ |
Benzodiazepine Screen |
Y |
Y |
UCOKE |
Cocaine Metabolites Screen |
Y |
Y |
UOP |
Opiate Screen |
Y |
Y |
UTHC |
Cannabinoid (THC) Screen |
Y |
Y |
Specimen Requirements
Container Type: |
Sterile urine cup
|
Optimal Collection Volume: |
5 mL |
Minimum Volume: |
1 mL |
Collection Instructions: |
1. Collect a random urine specimen from the patient. 2. Ensure the lid is secured tightly before sending it to the lab. 3. Ensure that no preservatives are used. |
Specimen Transport: |
Refrigerate (Recommended) |
Processing Instructions: |
1. Pour off urine into a labeled aliquot tube. 2. Centrifuge the urine aliquot. 3. Deliver the urine aliquot to the chemistry department. |
Specimen Stability
Specimen Type | Temperature | Time |
---|---|---|
Urine | Refrigerated | 5 days |
Specimen Rejection Criteria
Adulterated urine specimen
Useful For
Detecting drug abuse involving one or more of the following drugs:
- Amphetamines
- Barbiturates
- Benzodiazepines
- Cocaine
- Opiates
- Cannabinoids
Methodology
Roche Cobas - Kinetic interaction of particles in solution (KIMS)
Reference Ranges
Negative
Interpretive
Test ID | Methodology Comment |
---|---|
UAMP |
This assay detects amphetamine and methamphetamine at levels of 500 ng/mL and above. It also detects MDMA (Ecstasy) at levels of 200 ng/mL and above. Note: Labetalol and trazodone may also cause positive results with this drug screen. |
UBARB |
This assay detects secobarbital at 200 ng/mL and higher. Phenobarbital, pentobarbital, and other barbiturate compounds are also detectable.
|
UBENZ |
This assay detects nordiazepam at 100 ng/mL. Other benzodiazepine compounds are also detectable.
|
UCOKE |
This assay detects benzoylcognine at levels of 300 ng/mL and higher.
|
UOP |
This assay detects morphine at concentrations of 300 ng/mL and higher. Codeine and heroin are also detectable. This assay is less sensitive to hydrocodone, which is detected only at high concentrations. This assay does NOT detect other opioid analgesics. |
UTHC |
This assay detects tetrahydrocannabinol (THC) at levels of 50 ng/mL and higher.
|
Day(s) Performed
24/7
Expected TAT
Same day
Performing Laboratory
Bronson Laboratory, Chemistry - Kalamazoo, Battle Creek, Paw Paw, South Haven
Sample Retention Time
7 days
CPT Code
80307
LOINC Code
- UAMP: 19343-3
- UBARB: 19270-8
- UBENZ: 14316-4
- UCOKE: 14314-9
- UOP: 19295-5
- UTHC: 18282-4