Test Code URDS or LAB2286 Drug Screen 6, Urine
Profile Information
| 
 Test ID  | 
 Reporting Name  | 
 Available Separately?  | 
 Always Performed?  | 
|---|---|---|---|
| 
 UAMP  | 
 Amphetamine Screen  | 
 Y  | 
 Y  | 
| 
 UBARB  | 
 Barbiturate Screen  | 
 Y  | 
 Y  | 
| 
 UBENZ  | 
 Benzodiazepine Screen  | 
 Y  | 
 Y  | 
| 
 UCOKE  | 
 Cocaine Metabolites Screen  | 
 Y  | 
 Y  | 
| 
 UOP  | 
 Opiate Screen  | 
 Y  | 
 Y  | 
| 
 UTHC  | 
 Cannabinoid (THC) Screen  | 
 Y  | 
 Y  | 
Specimen Requirements
| Container Type: | 
 Sterile urine cup 
 
 
  | 
| Optimal Collection Volume: | 
 5 mL  | 
| Minimum Volume: | 
 1 mL  | 
| Collection Instructions: | 
 1. Collect a random urine specimen from the patient. 2. Ensure the lid is secured tightly before sending it to the lab. 3. Ensure that no preservatives are used.  | 
| Specimen Transport: | 
 Refrigerate (Recommended)  | 
| Processing Instructions: | 
 1. Pour off urine into a labeled aliquot tube. 2. Centrifuge the urine aliquot. 3. Deliver the urine aliquot to the chemistry department.  | 
Specimen Stability
| Specimen Type | Temperature | Time | 
|---|---|---|
| Urine | Refrigerated | 5 days | 
Specimen Rejection Criteria
Adulterated urine specimen
Useful For
Detecting drug abuse involving one or more of the following drugs:
- Amphetamines
 - Barbiturates
 - Benzodiazepines
 - Cocaine
 - Opiates
 - Cannabinoids
 
Methodology
Roche Cobas - Kinetic interaction of particles in solution (KIMS)
Reference Ranges
Negative
Interpretive
| Test ID | Methodology Comment | 
|---|---|
| UAMP | 
 This assay detects amphetamine and methamphetamine at levels of 500 ng/mL and above. It also detects MDMA (Ecstasy) at levels of 200 ng/mL and above. Note: Labetalol and trazodone may also cause positive results with this drug screen.  | 
| UBARB | 
 This assay detects secobarbital at 200 ng/mL and higher. Phenobarbital, pentobarbital, and other barbiturate compounds are also detectable. 
  | 
| UBENZ | 
 This assay detects nordiazepam at 100 ng/mL. Other benzodiazepine compounds are also detectable. 
  | 
| UCOKE | 
 This assay detects benzoylcognine at levels of 300 ng/mL and higher. 
  | 
| UOP | 
 This assay detects morphine at concentrations of 300 ng/mL and higher. Codeine and heroin are also detectable. This assay is less sensitive to hydrocodone, which is detected only at high concentrations. This assay does NOT detect other opioid analgesics.   | 
| UTHC | 
 This assay detects tetrahydrocannabinol (THC) at levels of 50 ng/mL and higher. 
  | 
Day(s) Performed
24/7
Expected TAT
Same day
Performing Laboratory
Bronson Laboratory, Chemistry - Kalamazoo, Battle Creek, Paw Paw, South Haven
Sample Retention Time
7 days
CPT Code
80307
LOINC Code
- UAMP: 19343-3
 - UBARB: 19270-8
 - UBENZ: 14316-4
 - UCOKE: 14314-9
 - UOP: 19295-5
 - UTHC: 18282-4