Test Code BOCA (LAB 2111) Blood Gas O2 SAT & Na, K, ICAL, Arterial (BOCA)
Profile Information
|
Test ID |
Reporting Name |
Available Separately |
Always Performed |
|---|---|---|---|
|
TEMP* |
Temperature |
N | Y |
|
FIO2* |
Inspired O2 |
N | Y |
|
HGB |
Hemoglobin |
N |
Y |
|
PH |
pH Arterial |
N | Y |
|
PCO2 |
pCO2 |
N | Y |
|
PO2 |
pO2 |
N | Y |
|
HCO3 |
HCO3 |
N | Y |
|
OXYHGB |
Oxyhemoglobin, Arterial |
N |
Y |
|
O2SAT |
O2 Saturation, Arterial |
N |
Y |
|
BBE or BBD |
Base Excess or Base Deficient |
N |
Y |
|
NA |
Sodium |
N |
Y |
|
K |
Potassium |
N |
Y |
|
ICAL |
Ionized Calcium |
N |
Y |
*Captured during specimen collection.
Specimen Requirements
| Container Type: |
Heparinzed syringe, whole blood
|
| Optimal Collection Volume: |
1 syringe (2 mL whole blood) |
| Minimum Volume: | 0.5 mL |
| Collection Instructions: |
|
| Specimen Transport: |
Refrigerate |
| Processing Instructions: |
|
Specimen Stability
Assay as soon as possible. Specimens are stable at room temperature for 30 minutes and 2 hours on ice.
Specimen Rejection Criteria
Quantity not sufficient
Useful For
Evaluating acid-base status
Evaluating disturbances in the partial pressure of carbon dioxide and oxygen in the blood
Evaluating total hemoglobin as oxygen saturation in the blood.
Methodology
Radiometer ABL 800 systems
- pH, pCO2, NA, K, ICAL - Potentiometric
- pO2 - Amperometric
- HCO3 - Calculated result
- Hemoglobin parameters - Optical system
Reference Ranges
|
Test ID |
Reference Range and Reporting Units |
|---|---|
|
HGB |
Gender and age-specific* |
|
PH |
7.35-7.45 |
|
PCO2 |
35-45 mm[Hg] |
|
PO2 |
80-90 mm[Hg] |
|
HCO3 |
21-28 mmol/L |
|
OXYHGB |
94-98 % |
|
O2SAT |
95-99 % |
|
NA |
135-145 mmol/L |
|
K |
3.5-5.3 mmol/L |
|
ICAL |
4.5-5.3 mg/dL |
Please click the Bronson Critical Values link to view Critical Values
* For HGB reference ranges, please link the Hematology Reference Ranges link.
Day(s) Performed
24/7
Expected TAT
Same day
Performing Laboratory
Bronson Laboratory, Chemistry - Kalamazoo, Paw Paw, South Haven
Sample Retention Time
Samples are discarded once per shift (every 8 hours)
CPT Code
- Blood gas - 82805
- NA - 84295
- K - 84132
- ICAL - 82330