Test Code UOP Opiates Drug Screen, Random, Urine
Additional Codes
Epic Code: LAB2278
Performing Laboratory
Bronson Laboratory Services-Chemistry
Reference Values
Negative
Methodology
Immunoassay
Methodology Comment: This assay detects morphine at concentrations of 300 ng/ml and higher. Codeine and Heroin are also detectable. This assay is lesssensitive to hydrocodone and hydromorphone which are detected only at higher concentrations.
Note: This assay does NOT detect other
opiod analgesics, specifically it does not detect
methadone, fentanyl,
oxycodone, buprenorphine, or propoxyphene. If there is a
question of therapeutic compliance or abuse of these drugs, a test
for the specific drug of interest should be ordered.
Note:
Drug screening performed at Bronson Laboratory Services is for medical purposes only. No chain of custody, or specimen adulteration testing is performed. All positive results are presumptive. Presumptive Positive means that this screening method is positive. A more specific alternative method must be used in order to obtain a confirmed analytical result. Confirmatory testing is available on request through our reference lab. Clinical consideration and professional judgment should b e applied to any drug of abuse test result, particularly with presumptive positive results.
If employment/legal drug screening is required, contact ProHealth Management Services at 269-341-7547.
Specimen Requirements
Specimen Type: Urine, random
Container/Tube: Plastic urine
container
Specimen Volume: 5 mL
Collection Instructions: No
preservative.
Specimen Transport Temperature
Refrigerate
Day(s) Test Set Up
Monday through Sunday
Test Classification and CPT Coding
80307